Dairy Equipment
JM series colloidal mills
Colloid pump
GS Series Screw pump
High-Shear Homogenizer
Kettle type emulsifier
Mix the pump
Suction powder mixer
Piping fittings
Pneumatic pulp pump
 
     
 
¡¡¡¡
Install and use conditions: Units generally horizontal installation. Transmission medium is -10 ~ 85 ¡É, the highest viscosity 20000mm2 / s, solid particle content (mass ratio) of up to 40%.

Hao Stars GS-type single-screw pump to use Considerations:
1.GS single-screw pump running pre-boot we must first determine the direction, shall not be reversed.
2.GS-type single-screw pump is strictly prohibited in the absence of media cases, empty running, so as to avoid damage to the stator.
3. The new installation or down a few days later G-type single-screw pump, can not immediately start, should first G-type single-screw pump body into the amount of oil, and then pipe clamp plate start moving only after a few trips.
4. Transport of high viscosity or containing particles and corrosive media, the application of water or solvent to wash, to prevent the obstruction, so as to avoid difficulties in the next start.
5. In winter should be fluid line to prevent the Frost Crack.
6.GS the process of using bearing-type screw pump should be regularly lubricating the box and found that when the shaft there is seepage, a timely processing or exchange seals.
7. In the event of abnormal operation should immediately stop checking reasons, troubleshooting.

Model Logo: Example

International Model logo

International Model logo


Pump Selection
Hao Stars GS-type single-screw pump design speed for the delivery of water or water similar to the non-corrosive liquids when the maximum speed allowed in the actual use of media property and life due to different requirements for use in general should be lower than when the design speed, right high viscosity and containing granular media in general a design speed of 1/2-1/3 more or less, low-speed on pump wear and tear of a favorable, but after use due to wear and tear of the stator flows have declined, this time may be appropriate to improve the speed to compensate for the drop in traffic for regular policy. Transmission medium temperature should be at -10 ¡É ~ 80 ¡É special cases up to 120 ¡É.
Hao Stars GS-type single-screw pump for each level (the stator of a lead) and normal pressure 0.3 ~ 0.6Mpa, short (not more than 30 minutes) to allow up to 0.6Mpa, when worn in the same volumetric efficiency of the output pressure should gradually decline.
Hao Stars GS-type single-screw pump to send the maximum absorption of water when the process is 3 meters, the actual use of the proposed no more than 2.5 m when pumping high viscosity media, should be based on positive pressure inhalation.

Selection Description
1, According to media wear selection speed:

Abrasion

Speed

Mild abrasion

710~520£¨r/min£©

Moderate abrasio

520~380£¨r/min£©

Severe abrasion

380~100£¨r/min£©

2, according to the output pressure set series:

Abrasion

1

Mild abrasion

0.6 MPa

Moderate abrasio

0.4 MPa

Severe abrasion

0.2 MPa

Note: Preliminary Category wear a variety of media:
a. mild abrasion medium: soft mud, water more than 95% of sewage, such as the activity of mud and water, refined sugar, waste water, industrial wastewater, livestock urine, paint, a variety of suspension.
b. Moderate Wear Medium: Solid material containing mud, water content, more than 85% of the sludge slurry, dyes, paints, molasses Grinding Fluid, gypsum mud, sediment filtered rapeseed oil.
c. severe abrasion media: hardness mud, containing a high abrasion solid liquid slurry, more than 50% moisture content of sludge, such as slurry, hot springs mud, lime mud, clay, plaster, potters, PVC slurry, dewatering sticky degree of agent.
3, according to pump transport medium containing the largest body of particle diameter and fiber length options

Pump Model

G10

G25

G35

G40

G50

G55

G60

Particle diameter (mm)

1.5

2.5

3

3.8

5

5.2

6.8

Fiber length (mm)

18

38

42

48

60

65

75

4, pump power required to transport multiple medium viscosity (ie choose motor power) and speed

Viscosity
(mpa¡¤s)

0~
10000

10000~
25000

25000~
500000

50000~
100000

100000~
150000

Power multiples

1.0

1.05

1.1

1.2

1.25

Speed

710~520

520~380

380~280

280~200

200~100

5, by feeding the form of options: pressure and levels of delivery selected a pump; negative pressure and suction pump conveying the election two
6, pumps transport liquids containing solid density, power multiples are also different, according to N = M / M Shimizu N Shimizu
7, according to the physical and chemical properties of pump delivery medium, select the pump and filter parts of the work material
 
   
Copyright©2001 Zhejiang Hao Star Machinery Equipment Manufacturing Co., Ltd. All Rights Reserved
Tel:+86-577-86999999  86830999  Fax:+86-577-86827859
Connect with us: E-mail:cn7s@163.net